Excalibur now has RT Mode in Exalt

14.05.2009

MIL-STD-1553 RT Mode

In addition to BC concurrent mode and monitor mode. Exalt now completes the functionality of MIL-STD-1553 with support for Remote Terminal Mode (RT Mode). Each module may be configured to simulate up to 32 RT's, with the user selecting which RT's are active. Options to inject communication errors or status word errors into the message responses are available.  A maximum of 256 data blocks may be associated with a particular RT/SA combination. Data blocks may be defined as static data or dynamic data using Exalts standard engineering units and functions.

Error Injection

  • Error Injection
    • Bit Count
    • Non-contiguous
    • Status Parity
    • Status Sync
    • Data Parity
    • Data Sync
  • Status Word
    • Return RT address
    • Message Error
    • Service Request
    • Instrumentation
    • Broadcast
    • Subsystem Flag
    • Dynamic Bus
    • Terminal Flag
    • Busy
  • Word Count
  • Set Vector Count
  • Bit Word

Single Function PxS MIL-STD-1553

Exalt also supports Excalibur's new single function PxS MIL-STD-1553 module. Clients using Exalt with single function will have all the features of Exalt available, but will only be able to define a single RT without error injection options.